3516E Generator Set
3000 - 3500 kVA Diesel Generator Set
More Comfort – More Performance – More Versatility
-
Saves up to 16% installed space
Requires less space for installation
-
Weighs up to 30% less
Reduced amount of structural support required
-
Full Power up to 50°C Ambient
Provides full power even on hottest days of the year
Generator Set Specifications
Duty Cycle | Standby, Mission Critical, Prime |
Emissions/Fuel Strategy | U.S. EPA Cert. Tier 2 / Low NOx |
Frequency | 50 Hz |
Maximum Rating | 3500 kVA |
Minimum Rating | 2725 kVA |
Prime Power Rating | 3175/2950/2725 kVA |
Speed | 1500 rpm |
Standby Rating | 3500/3250/3000 kVA |
Voltage | 380 to 11000 volts |
Engine Specifications
Aspiration | ATAAC |
Bore | 6.69 in |
Compression Ratio | 14.0:1 |
Displacement | 4765 inÂł |
Engine Model | 3516E, V-16, 4-Stroke Water-Cooled Diesel |
Fuel System | Electronic Unit Injection |
Governor Type | Adem™ A5 |
Stroke | 8.46 in |
Generator Set Dimensions
Dry Weight - Genset (maximum) | 45651 lb |
Dry Weight - Genset (minimum) | 44930 lb |
Height - Maximum | 131.6 in |
Height - Minimum | 131.6 in |
Length - Maximum | 318.4 in |
Length - Minimum | 313.4 in |
Width - Maximum | 104 in |
Width - Minimum | 104 in |
Download resources
Electric Power Ratings Guide
3516E, 50 Hz, 2950 - 3500 kVA, Tier 2 Spec Sheet
3516E, 50Hz 2950 - 3500 kVA Low NOx Spec Sheet
3516E, 50Hz 2725 - 3000 kVA, Tier 2 (EPA ESE) with Low NOx Spec Sheet
3516E, 50 Hz, 2950/3175 kVA, Prime-DCP, Tier 2 Equivalent US. EPA Stationary Emergency Spec Sheet
3516E, 50 Hz, 2950/3175 kVA, Prime-DCP, Low NOx Spec Sheet
3516E, 50 Hz, 2725 kVA, Prime-DCP, Tier 2 (EPA ESE) with Low NOx Spec Sheet
Get info about our financing options
Get The best solution for your job site needs
Let us help.
Generator Set Specifications
Duty Cycle | Standby, Mission Critical, Prime |
Emissions/Fuel Strategy | U.S. EPA Cert. Tier 2 / Low NOx |
Frequency | 50 Hz |
Maximum Rating | 3500 kVA |
Minimum Rating | 2725 kVA |
Prime Power Rating | 3175/2950/2725 kVA |
Speed | 1500 rpm |
Standby Rating | 3500/3250/3000 kVA |
Voltage | 380 to 11000 volts |
Engine Specifications
Aspiration | ATAAC |
Bore | 6.69 in |
Compression Ratio | 14.0:1 |
Displacement | 4765 inÂł |
Engine Model | 3516E, V-16, 4-Stroke Water-Cooled Diesel |
Fuel System | Electronic Unit Injection |
Governor Type | Adem™ A5 |
Stroke | 8.46 in |
Generator Set Dimensions
Dry Weight - Genset (maximum) | 45651 lb |
Dry Weight - Genset (minimum) | 44930 lb |
Height - Maximum | 131.6 in |
Height - Minimum | 131.6 in |
Length - Maximum | 318.4 in |
Length - Minimum | 313.4 in |
Width - Maximum | 104 in |
Width - Minimum | 104 in |