fbpx
Skip to content
C175-16 Generator Set

C175-16 Generator Set

2500 - 3365 ekW Diesel Generator Set

More Comfort – More Performance – More Versatility

  • Over 20,000,000 Operating hours

    at Global locations

  • Over 3000 units

    In the field

  • Highest Rated Tier 4 Product

    Available on the market

Generator Set Specifications

Duty Cycle Standby, Mission Critical, Prime, Continuous
Emissions/Fuel Strategy Low Fuel, Tier 2
Frequency 60 Hz
Maximum Rating 3365 ekW
Minimum Rating 2500 ekW
Prime Power Rating 3115(no fan)/3000/2825(no fan)/2725 ekW
Speed 1800 RPM
Standby Rating 3365(no fan)/3250/3100(no fan)/3000 ekW
Voltage 480 to 13800 Volts

Engine Specifications

Aspiration Turbo Aftercooled
Bore 6.89 in
Compression Ratio 16.7:1
Displacement 6456.31 in³
Engine Model C175-16 SCAC, V-16, 4-Stroke Water-Cooled Diesel
Fuel System Common Rail
Governor Type ADEM� A4
Stroke 8.66 in

Generator Set Dimensions

Dry Weight - Genset (maximum) 50500 lb
Dry Weight - Genset (minimum) 42750 lb
Height - Maximum 134.3 in
Height - Minimum 87 in
Length - Maximum 312.9 in
Length - Minimum 241.6 in
Width - Maximum 113.7 in
Width - Minimum 83.1 in

Download resources

Electric Power Rating Guide
C175-16, 60 Hz, 3000 ekW Standby/MC.2725 ekW Prime, 2500 ekW Cont., Low Fuel Consumption (with fan) Spec Sheet
C175-16, 60 Hz, 3000 ekW Standby/MC.2725 ekW Prime, 2500 ekW Cont., U.S. EPA Stationary Emergency (Tier 2) (with fan) Spec Sheet
C175-16, 60 Hz, 3100 ekW Standby/MC, 2825 ekW Prime, 2600 ekW Cont., Low Fuel Consumption (without fan) Spec Sheet
C175-16, 60 Hz, 3100 ekW Standby/MC, 2825 ekW Prime, 2600 ekW Cont., U.S. EPA Stationary Emergency (Tier 2) (without fan) Spec Sheet
C175-16, 60 Hz, 3250 ekW Standby/MC, 3000 ekW Prime, U.S. EPA Stationary Emergency (Tier 2) (with fan) Spec Sheet
C175-16, 60 Hz, 3365 ekW Standby/MC, 3115 ekW Prime, U.S. EPA Stationary Emergency (Tier 2) (without fan) Spec Sheet
C175-16, 60 Hz, 2725 ekW, Prime-DCP, U.S. EPA Stationary Emergency Use Only (Tier 2) (with fan) Spec Sheet
C175-16, 60 Hz, 2725 ekW, Prime-DCP, Low Fuel Consumption (with fan) Spec Sheet
C175-16, 60 Hz, 2825 ekW, Prime-DCP, U.S. EPA Stationary Emergency Use Only (Tier 2) (without fan) Spec Sheet
C175-16, 60 Hz, 2825 kVA, Prime-DCP, Low Fuel Consumption (without fan) Spec Sheet
C175-16, 60 Hz, 3000 ekW, Prime-DCP, U.S. EPA Stationary Emergency Use Only (Tier 2) (with fan) Spec Sheet
C175-16, 60 Hz, 3115 ekW, Prime-DCP, U.S. EPA Stationary Emergency Use Only (Tier 2) (without fan) Spec Sheet

Get info about our financing options

Get The best solution for your job site needs

Let us help.

Name(Required)
Untitled

Call us today: 1-877-778-2230
or  Send us a message