C2.2 Generator Set
13 - 22 kVA Diesel Generator Set
More Comfort – More Performance – More Versatility
-
Over 1000 Hours Continuous Run Time
-
Remote Connectivity 24/7/365 Monitoring
Cat Connect option ensures your generator set is always ready to start and performing as expected
-
Reliability tested for over 500 Hours in Harsh & Testing environments
Generator Set Specifications
Duty Cycle | Standby, Prime |
Emissions/Fuel Strategy | R96/EUIIIa Equivalent |
Frequency | 50 Hz |
Maximum Rating | 22.0 kVA |
Minimum Rating | 13.0 kVA |
Speed | 1500 rpm |
Voltage | 110 to 415 Volts |
Engine Specifications
Aspiration | Naturally Aspirated |
Bore | 3.3 in |
Compression Ratio | 22.5:1 |
Displacement | 135.2 inÂł |
Engine Model | Cat® C2.2, In-line 4, 4-cycle diesel |
Fuel System | Indirect Injection |
Governor Type | Mechanical |
Stroke | 3.9 in |
Generator Set Dimensions
Height - Maximum | 43.9 in |
Length - Maximum | 59.1 in |
Width - Maximum | 24.4 in |
Download resources
DE22E3 50 Hz 22.0 kVA, 60 Hz 25.0 kVA, M Frame, EU IIIA Emissions Compliant Spec Sheet
Electric Power Ratings Guide
DE14E3S 50 Hz 14.0 kVA, 60 Hz 17.0 kVA, M Frame, EU IIIA Compliant Emissions Spec Sheet
DE16E3S 50 Hz 16.5 kVA, 60 Hz 19.4 kVA, M Frame, EU IIIA Emissions Compliant Spec Sheet
DE18E3 50 Hz 18.0 kVA, 60 Hz 22.0 kVA, M Frame, EU IIIA Compliant Emissions Spec Sheet
DE14E3S 50 Hz 14.0 kVA, 60 Hz 17.0 kVA, LC Frame, EU IIIA Emissions Compliant Spec Sheet
DE16E3S 50 Hz 16.5 kVA, 60 Hz 19.4 kVA, LC Frame, EU IIIA Emissions Compliant Spec Sheet
DE18E3 50 Hz 18.0 kVA, 60 Hz 22.0 kVA, LC Frame, EU IIIA Emissions Compliant Spec Sheet
DE22E3 50 Hz 22.0 kVA, 60 Hz 25.0 kVA, LC Frame, EU IIIA Emissions Compliant Spec Sheet
C1C2 Diesel Generator Set, 6.8 - 22 kVA, 50/60 Hz Spec Sheet
C1C2 Diesel Generator Set, 6.8 - 22 kVA, 50/60 Hz Spec Sheet
Get info about our financing options
Get The best solution for your job site needs
Let us help.
Generator Set Specifications
Duty Cycle | Standby, Prime |
Emissions/Fuel Strategy | R96/EUIIIa Equivalent |
Frequency | 50 Hz |
Maximum Rating | 22.0 kVA |
Minimum Rating | 13.0 kVA |
Speed | 1500 rpm |
Voltage | 110 to 415 Volts |
Engine Specifications
Aspiration | Naturally Aspirated |
Bore | 3.3 in |
Compression Ratio | 22.5:1 |
Displacement | 135.2 inÂł |
Engine Model | Cat® C2.2, In-line 4, 4-cycle diesel |
Fuel System | Indirect Injection |
Governor Type | Mechanical |
Stroke | 3.9 in |
Generator Set Dimensions
Height - Maximum | 43.9 in |
Length - Maximum | 59.1 in |
Width - Maximum | 24.4 in |