C4.4 Generator Set
72 - 100 ekW Diesel Generator Set
More Comfort – More Performance – More Versatility
-
Suitable for Harsh & Testing Environments
-
Optimised for 5% Lower Fuel Consumption
Longer run times between fuel fills; reduced operating costs
-
Reliability tested for minimum 500 Hours
Ensures you can count on emergency power when it is needed
Generator Set Specifications
| Duty Cycle | Standby, Prime |
| Emissions/Fuel Strategy | U.S. EPA Tier 3 Certified / SCAQMD |
| Frequency | 60 Hz |
| Prime Power Rating | 36/45/55/72/90 ekW |
| Speed | 1800 rpm |
| Standby Rating | 40/50/60/80/100 ekW |
| Voltage | 110 to 480 Volts |
Engine Specifications
| Aspiration | Turbocharged |
| Bore | 4.1 in |
| Compression Ratio | 16.2:1, 17.25:1, 18.2:1 or 18.3:1 |
| Displacement | 268.5 inÂł |
| Engine Model | Cat® C4.4 |
| Fuel System | Direct Injection or Common Rail |
| Governor Type | Mechanical |
| Stroke | 5 in |
Generator Set Dimensions
| Height - Maximum | 53.6 in |
| Length - Maximum | 75.8 in |
| Width - Maximum | 44.1 in |
Download resources
Electric Power Ratings Guide
60 Hz 80 ekW, EPA Tier III Compliant Emissions Spec Sheet
60 Hz 100 ekW, EPA Tier III Compliant Emissions Spec Sheet
C4.4, Diesel Generator Set, 60 Hz, 80 -100 ekW, Spec Sheet
60 Hz 40 ekW, EPA Tier III Compliant Emissions Spec Sheet
60 Hz 60 ekW, EPA Tier III Compliant Emissions Spec Sheet
60 Hz 50 ekW, EPA Tier III Compliant Emissions Spec Sheet
60 Hz 36 ekW, SCAQMD & US EPA Tier 3 equivalent Compliant Emissions Spec Sheet
60 Hz 40 ekW, SCAQMD & US EPA Tier 3 equivalent Compliant Emissions Spec Sheet
60 Hz 45 ekW, SCAQMD & US EPA Tier 3 equivalent Compliant Emissions Spec Sheet
60 Hz 50 ekW, SCAQMD & US EPA Tier 3 equivalent Compliant Emissions Spec Sheet
60 Hz 60 ekW, U.S. EPA Certified for Stationary Emergency Application Compliant Emissions Spec Sheet
60 Hz 55 ekW, U.S. EPA Certified for Stationary Emergency Application Compliant Emissions Spec Sheet
Get info about our financing options
Get The best solution for your job site needs
Let us help.
Generator Set Specifications
| Duty Cycle | Standby, Prime |
| Emissions/Fuel Strategy | U.S. EPA Tier 3 Certified / SCAQMD |
| Frequency | 60 Hz |
| Prime Power Rating | 36/45/55/72/90 ekW |
| Speed | 1800 rpm |
| Standby Rating | 40/50/60/80/100 ekW |
| Voltage | 110 to 480 Volts |
Engine Specifications
| Aspiration | Turbocharged |
| Bore | 4.1 in |
| Compression Ratio | 16.2:1, 17.25:1, 18.2:1 or 18.3:1 |
| Displacement | 268.5 inÂł |
| Engine Model | Cat® C4.4 |
| Fuel System | Direct Injection or Common Rail |
| Governor Type | Mechanical |
| Stroke | 5 in |
Generator Set Dimensions
| Height - Maximum | 53.6 in |
| Length - Maximum | 75.8 in |
| Width - Maximum | 44.1 in |