Skip to content
C7.1 ACERT

C7.1 ACERT

135 - 220 kVA Diesel Generator Set

More Comfort – More Performance – More Versatility

  • Suitable for Harsh & Testing environments

  • Optimised for 5% Lower Fuel Consumption

    Longer run times between fuel fills; reduced operating costs

  • Reliability tested for over 500 Hours

    Ensures you can count on emergency power when it is needed

Generator Set Specifications

Duty Cycle Standby, Prime
Emissions/Fuel Strategy Low BSFC / EU Stage IIIA
Frequency 50 Hz
Prime Power Rating 135/150/160/180/200 kVA
Speed 1500 rpm
Standby Rating 150/165/175/200/220 kVA
Voltage 110 to 480 Volts

Engine Specifications

Aspiration Turbocharged, Air to Air Aftercooled
Bore 4.1 in
Compression Ratio 16.0:1, 18.2:1
Displacement 427.8 in
Engine Model Cat® C7.1
Fuel System Direct Injection
Governor Type Mechanical
Stroke 5.3 in

Generator Set Dimensions

Height - Maximum 64 in
Length - Maximum 98.4 in
Width - Maximum 52 in

Download resources

Electric Power Ratings Guide
DE150E0 50 Hz 150.0 kVA Standby, 50 Hz,135.0 kVA Prime, LC-Frame, Low BSFC Compliant Spec Sheet
DE165E0 50 Hz 165.0 kVA Standby, 50 Hz 150.0 kVA Prime, LC-Frame, Low BSFC Compliant Spec Sheet
DE165E3 50 Hz 165.0 kVA, LC-Frame, EU IIIA Compliant Spec Sheet
DE175E3 50 Hz 175.0 kVA, LC-Frame, EU IIIA Compliant Spec Sheet
DE200E0 50 Hz 200.0 kVA Standby, 50 Hz, 180.0 kVA Prime, LC-Frame, Low BSFC Compliant Spec Sheet
DE200E3 50 Hz 200.0 kVA, LC-Frame, EU IIIA Compliant Spec Sheet
DE220E0 50 Hz 220.0 kVA, LC-Frame, Low BSFC Compliant Spec Sheet
DE150E0 50 Hz 150.0 kVA, M-Frame, Low BSFC Compliant Spec Sheet
DE165E0 50 Hz 165.0 kVA, M-Frame, Low BSFC Compliant Spec Sheet
DE165E3 50 Hz 165.0 kVA, M-Frame, EU IIIA Compliant Spec Sheet
DE200E0 50 Hz 200.0 kVA, M-Frame, Low BSFC Compliant Spec Sheet
DE200E0 50 Hz 200.0 kVA, M-Frame, Low BSFC Compliant Spec Sheet
DE200E3 50 Hz 200.0 kVA, M-Frame, EU IIIA Compliant Spec Sheet
DE220E0 50 Hz 200.0 kVA, M-Frame, Low BSFC Compliant Spec Sheet
DE165E0 50 Hz 165.0 kVA, 60 Hz 187.5 kVA, R-Frame, Low BSFC Compliant Spec Sheet
DE165E0 50 Hz 165.0 kVA, 60 Hz 187.5 kVA, R-Frame, Low BSFC Compliant Spec Sheet
DE200E0 50 Hz 200.0 kVA, 60 Hz 218.8 kVA, R-Frame, Low BSFC Compliant Spec Sheet
DE165E3 50 Hz 165.0 kVA, R-Frame, EU IIIA Compliant Spec Sheet
DE220E0 50 Hz 220.0 kVA, R-Frame, Low BSFC Compliant Spec Sheet

Get info about our financing options

Get The best solution for your job site needs

Let us help.

Related Products

30-220 kVA SA Lvl 1 Enclosure
30-220 kVA SA Lvl 1 Enclosure

Generator Set Specifications

Duty Cycle Standby, Prime
Emissions/Fuel Strategy Low BSFC / EU Stage IIIA
Frequency 50 Hz
Prime Power Rating 135/150/160/180/200 kVA
Speed 1500 rpm
Standby Rating 150/165/175/200/220 kVA
Voltage 110 to 480 Volts

Engine Specifications

Aspiration Turbocharged, Air to Air Aftercooled
Bore 4.1 in
Compression Ratio 16.0:1, 18.2:1
Displacement 427.8 in
Engine Model Cat® C7.1
Fuel System Direct Injection
Governor Type Mechanical
Stroke 5.3 in

Generator Set Dimensions

Height - Maximum 64 in
Length - Maximum 98.4 in
Width - Maximum 52 in

Call us today: 1-877-778-2230